HLogStop (Function) In french: HJournalStop
Available only with these kinds of connection
Stops the log process of a data file. The operations performed in the logged file are not saved anymore. HLogInfo(Customer, "start printing " + Criterion) HLogStop(Customer)  // Stop the log HReadFirst(Customer, Criterion) WHILE HFound() = True // Process  HReadNext(Customer) END  // Restart log HLogRestart(Customer) // Write to log HLogInfo(Customer, "end of print of " + Criterion) Syntax
<Result> = HLogStop(<Data file>)
<Result>: Boolean - True if the operation was performed,
- False if a problem occurs. HError is used to identify the error.
<Data file>: Character string Name of the logged data file whose log process must be stopped. Remarks - The operations performed once this function has been used will not be logged and they will be lost if a problem occurs.
- Don't forget to restart the log process via HLogRestart and make sure that the data file strictly has its initial status.
- The log is stopped until HLogRestart is run.